Viking CRVDD336R Range User Manual


 
6
Downdraft VentilatorsVIKING RANGE, LLC
PREPARE THE DOWNDRAFT
Exterior Blower Installation
The downdraft is shipped without a blower. Purchase a Model
VEDV900 Exterior Blower and mount the 10" discharge plate
to the downdraft as follows:
1. Place the downdraft on its back on a table of flat work surface.
2. Remove the 4 nuts and 2 clamp channels.
3. Remove 2 screws and the gear motor cover.
4. Carefully position the10" discharge plate under the bottom
flange of the downdraft.
5. Connect motor plug.
6. Replace the gear motor cover and 2 sheet metal screws.
7. Replace the 2 clamp channels and start the 4 nuts, do not
tighten.
8. Slide blower left of right to desired position. Use cover plate
(supplied) to close up any open space.
9. Tighten 4 nuts to secure top of blower. Use additional screws
(supplied) through bottom flange to secure bottom of discharge
plate.
NUTS
COVER
PLATE
CLAMP
CHANNELS
SCREWS
GEARMOTOR
COVER
MOTOR
PLUG
10" ROUND
DISCHARGE
PLATE
ADDITIONAL
SCREWS
BOTTOM
FLANGE
CUT COUNTERTOP OPENING
All Units
1. Measure and cut the countertop opening for your width of
cooktop and downdraft.
Cooktop Width & Model
30" RVGC3305B 36" RVGC3365B 45" RVEC3456B
30" RVEC3305B 36" RVEC3365B 45" CRVEC3456B
30" CRVGC3305B 36" CRVGC3365B
30" CRVEC3305B 36" CRVEC3365B
For use with Downdraft Models RVDD330R RVDD336R RVDD345R
CRVDD330R CRVDD336R CRVDD345R
Cutout Dimensions A 29-1/8" 34-7/8" 42-7/8"
B 20-5/8" 20-5/8" 20-5/8"
C 27" 33" 42"
D 2-1/4" 2-1/4" 2-1/4"
E 1-1/16" 15/16" 7/16"
F 1-1/16" 15/16" 7/16"
A
C
B
D
F
E
BLOWER MODEL DIMENSIONS
VIDV500 18.25" x 18.214" x 7.569"
VEDV900 28.25" x 24.75" x 7.16"
VEDV1200 22" x 30.828" x 12.724"