Viking DBCV3082 Ventilation Hood User Manual


 
98
Settings and Functions
Hood Operation
Always turn on your hood before you begin cooking to
establish airflow in the kitchen. Also let the blower run for a few
minutes to clear the air after you turn off your cooking
appliance. This will help keep the kitchen air cleaner.
Professional Hoods
ON/OFF switch—Starts and stops the blower. When turned on
the blower will operate at the previous setting of the speed
control.
Blower speed knob—Turn the knob counterclockwise to
decrease the blower speed and clockwise to increase speed.
The type of cooking you are doing will dictate the speed of the
blower you use.
Light switch—Controls the 50-watt halogen lights located in
the front of the hood.
Dimmer knob—Turn the knob clockwise to brighten the
halogen lights and counterclockwise to dim the lights.
Heat lamp switches—Turn the heat lamps on and off.
Each professional wall hood will be equipped with one or two
heat lamp outlets. The 250-watt infrared bulbs are not
included and should be purchased locally.
Product Controls/Operation
Settings and Functions
Product Controls/Operation
CAUTION
DO NOT place flammable material on warming shelves
when using heat lamps.
Light knob—Push once to turn lights on. Push again to turn
lights off. Rotate clockwise to increase light intensity and
counterclockwise to decrease light intensity. Light setting will
stay the same when turned on or off.
Fan knob—Push once to turn blower on. Push again to turn
blower off. Rotate clockwise to increase blower speed and
counterclockwise to decrease blower speed.
Digital display—Remains blank while timer/delay functions are
not in use. Displays desired set time which is set by either the
set button or delay function button. Upon reaching 00:00, the
buzzer will sound and will continue to beep every 10 seconds
up to 5 minutes.
Delay feature button—Pushing this button once will
automatically set the digital display to 10 minutes. Pushing
again will go to 20 minutes and so forth, up to 30 minutes. The
blower will activate and the timer will start counting down until
00:00 is reached. At this time the display will go blank and blower
will cut off.
Scroll up button—Changes timer display upward to 12 hours.
Scroll down button—Changes timer display downward to 00:00.
Set button—Pushing once will activate display (00:00) and
allow you to enter time using the scroll up or scroll down
buttons. The blower cannot be activated using the set button.
Only the timer will be activated. Upon reaching 00:00, the
buzzer will sound and will continue to beep every 10 seconds
up to 5 minutes.
Designer Hoods