Viking DEV1200 Ventilation Hood User Manual


 
READ AND SAVE THESE INSTRUCTIONS
MODEL DEV1200
EXTERIOR MOUNTED VENTILATOR
FOR USE WITH VIKING VCWH, VICH, DBCV, DICV, DCWH, DCWL, DCWN,
DTWS AND DCIH RANGE HOODS. 30" TO 66" WIDE, 9" TO 18" HIGH.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manu-
facturer. If you have questions, contact the manufac-
turer or your distributor.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Soci-
ety for Heating, Refrigeration and Air Conditioning Engi-
neers (ASHRAE), and the local code authorities.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum.
PLAN THE
INSTALLATION
1. Locate the ventilator so
the length of the duct run
and number of elbows
needed are kept to a mini-
mum.
2. Where possible, ventilator
should be centered be-
tween wall studs or roof
rafters.
3. Avoid pipes, wires, or other
ductwork that may be run-
ning through the wall.
ALL INSTALLATIONS
MODEL VOLTS AMPS CFM DUCT SIZE
DEV1200 120 3.0 1200 10" DIA.
SPECIFICATIONS
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
TYPICAL ROOF MOUNTED INSTALLATION TYPICAL WALL MOUNTED INSTALLATION
5. When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
WARNING
MODEL DEV1200
EXTERIOR VENTILATOR
10" ROUND
DUCT
SOFFIT
WALL HOOD
CANOPY
(island canopy available)
MODEL
DEV1200
EXTERIOR
VENTILATOR
10" ROUND DUCT
SOFFIT
10" ROUND ELBOW
WALL HOOD
CANOPY
(island canopy available)
Blower Dimensions
22 x 30.828 x 12.724