Viking DFRB304 Refrigerator User Manual


 
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
REFRIGERATION
Built-In 30”W. All Refrigerator
RELEASED 12/1/07
©2007 VRC—INFORMATION SUBJECT TO CHANGE
UTILITY
REQUIREMENTS
GAS
Not applicable
ELECTRICAL
• Three-wire cord
with
grounded
three-prong plug
attached to
product
• 115 VAC/60 Hz;
15 amp
dedicated circuit
• Maximum amp
usage—5.7
• Estimated
energy usage—
404 kWh/year
PLUMBING
Not applicable
Installation Requirements
Anti-tip board
6”
(15.2 cm)
9”
(22.9 cm)
73-3/8”
(186.4 cm)
82-7/8”
(210.5 cm) min.
anti-tip board &
opening height
84-1/16”
(21
3.5 cm) max.
anti-t
ip board &
opening height
29-1/2”
(7
4.9
cm
) mi
n
.
to
29-3/4”
(75.6
cm)
max.
Pro
fessional
30”
(7
6.2
cm)
Design
e
r/Cus
t
om Front
24”*
(61.0 cm)
min.
9”
(22.9 cm)
VCRB304 DDRB304 DFRB304
Cutout width 29-1/2” (74.9 cm) min. to 30” (76.2 cm) 30” (76.2 cm)
29-3/4” (75.6 cm) max.
Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.
Cutout depth 24” (61.0 cm) min.*
VCRB304
Professional
DDRB304
Designer
DFRB304
Custom Front
See Custom Panels section for
more information and additional
specifications.
ACCESS REQUIREMENTS – Single Installation
ELECTRIC OUTLET LOCATION
*Custom front models fit flush in 25”-deep (63.5 cm) cabinet openings. They can be installed in standard 24”-
deep openings. The door faces and top grille will protrude 3/4” (1.9 cm) into the room.