REFRIGERATION
Built-In 48”W. Side-By-Side
Refrigerator/Freezer with Dispenser
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
RELEASED 12/1/07
©2007 VRC—INFORMATION SUBJECT TO CHANGE
UTILITY
REQUIREMENTS
GAS
Not applicable
ELECTRICAL
• Three-wire cord
with grounded
three-prong plug
attached to
product
• 115 VAC/60 Hz;
15 amp dedicat-
ed circuit
• Maximum amp
usage—11.5
• Estimated
energy usage—
727 kWh/year
PLUMBING
• Inlet waterline
requirements—
1/4” copper
tubing
• 35 psi min.;
120 psi max.
Installation Requirements
Anti-tip board
6”
(15.2 cm)
9”
(22.9 cm)
6-3/4”
(17.1 cm)
7-5/8”
(19.4 cm)
3”
(7.6 cm)
5/8”
(1.5 c
m)
5/8
”
(1.5 cm)
10-1/2”
(26.7 cm)
5/8”
(1.5 cm)
10-
3/4”
(27.3 cm)
1”
(2.5 cm)
3-5/8”
(9.
2 cm
)
Optional floor
water line entry
9”
(22.9 cm)
73-3/8”
(186.4 cm)
82-7/8”
(210.5 cm) min.
anti-tip
board &
opening height
84-1/16”
(213.5 cm) max.
ant
i-tip board &
opening h
eight
24”*
(61.0 cm) min.
47-1/2” min.
(120.7 cm)
to
47-3/4” max.
(121.3
cm)
Professiona
l
48”
(121.9
cm)
Professional
Integra
te
d/
Designer/Custom Front
ACCESS REQUIREMENTS
VCSB483D VISB483D DDSB483D DFSB483D
Cutout width 47-1/2” (120.7 cm) min. to 48” (121.9 cm) 48” (121.9 cm) 48” (121.9 cm)
47-3/4” (121.3 cm) max.
Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max.
Cutout depth 24” (61.0 cm) min.*
VCSB483D/VISB483D
Professional/Professional
Integrated
DDSB483D
Designer
DFSB483D
Custom Front
See Custom Panels section for
more information and additional
specifications.
ELECTRIC OUTLET LOCATION
WATERLINE ENTRY AREA
*Custom front models fit flush in 25”-deep (63.5 cm)
cabinet openings. They can be installed in standard
24”-deep openings. The door faces and top grille
will protrude 3/4” (1.9 cm) into the room.