Viking VCIH Ventilation Hood User Manual


 
VIH Professional
Island Hood
VCIH Professional Classic
Chimney Island Hood
DCIH Designer Chimney
Island Hood
Proper installation/ducting is extremely
important to ensure maximum
performance. Use a qualified and
trained installer.
DUCTING
• Check with a qualified and
trained installer or local codes
for makeup air requirements,
if any.
• Max. duct run
o For 300 – 1,200 CFM—50’
(152.4 m)
o For 1,500 CFM—75’ (22.9 m)
o Duct run length is for general
reference only; for longer
duct runs, increase duct size
and contact a qualified and
trained installer.
o Straight runs and gradual
turns are best; for example,
each 90° elbow is equivalent
to 5’ – 10’ (1.52 – 3.05 cm) of
straight run.
7” (17.8 cm) round duct for
300 – 600 CFM; 10” for 900 –
1500 CFM
o Never use flexible duct; it
creates back pressure/air
turbulence and greatly
reduces performance.
GAS
Not applicable
ELECTRICAL
• Hardwire direct with two-wire
with ground
• 120 VAC/60 Hz
• Max. amp usage (rating
includes rec. ventilator kit
rating)
PLUMBING
Not applicable
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
RELEASED 12/1/07
©2007 VRC—INFORMATION SUBJECT TO CHANGE
VENTILATION
Built-In Island/Classic Chimney Island Hood
Installation Requirements
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs.
Note: Maximum amp rating for hoods includes recommended ventilator kit rating. All products must be hard wired with two-wire ground. An interior- or
exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
Model Ventilator Kits Duct Size Max. Amps
Interior Exterior Interior Exterior Interior Exterior
VIH3608 VIV600/1200* VEV900/1200* 7” (17.8 cm)/ 10” (25.4 cm) 4.9/7.4 7.4/4.7
10” (25.4 cm)
VIH4208 VIV600/1200* VEV900/1200/1500* 7” (17.8 cm)/ 10” (25.4 cm) 4.9/7.4 7.4/4.7/5.5
10” (25.4 cm)
VIH5408 VIV1200* VEV1200/1500** 10” (25.4 cm) 10” (25.4 cm) 8.2 5.5/6.2
VIH6608 VIV1200* VEV1200/1500** 10” (25.4 cm) 10” (25.4 cm) 8.2 5.5/6.2
VCIH3608 DIV600* DEV900/1200* 7” (17.8 cm) 10” (25.4 cm) 3.9 6.6/3.9
VCIH4208 DIV600* DEV900/1200/1500* 7” (17.8 cm) 10” (25.4 cm) 4.7 7.4/4.8/5.5
VCIH5408 DIV1200* DEV1200/1500** 10” (25.4 cm) 10” (25.4 cm) 8.6 5.6/6.4
VCIH6608 DIV1200* DEV1200/1500** 10” (25.4 cm) 10” (25.4 cm) 9.5 6.5/7.3
DCIH3604 DIV600 DEV900/DEV1200* 7” (17.8 cm) 10” (25.4 cm) 4.7 8.6
DCIH4204 DIV600 DEV1200/DEV1500** 7” (17.8 cm) 10” (25.4 cm) 4.7 7.4/4.7/5.5
DCIH5404 DIV1200* DEV1200/DEV1500** 10” (25.4 cm) 10” (25.4 cm) 8.6 5.6/6.4
Note: All CFMs are based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be
greatly overstated.