2”
(5.1 cm)
Dia.
2-3/4”
(7.0 cm)
4-3/8”
(11.1 cm)
2-1/2”
(6.4 cm)
1-3/4”
(4.4 cm)
31-1/16”
(78.9 cm)
28-5/16”
(71.9 cm)
23-7/16”
(59.5 cm)
Gas or Electrical
connection in
this area
Gas connection
in this area
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
RELEASED 12/1/07
©2007 VRC—INFORMATION SUBJECT TO CHANGE
VGSC307-4B VGSC367-6B VGSC367-4G VGSC367-4Q
Surface burner rating
Four grated burners (each) 15,000 BTU Nat. (4.4 kW)/ 15,000 BTU Nat. (4.4 kW)/ 15,000 BTU Nat. (4.4 kW)/
13,500 BTU LP (4.0 kW) 13,500 BTU LP (4.0 kW) 13,500 BTU LP (4.0 kW)
Six grated burners (each) 15,000 BTU Nat. (4.4 kW)/
13,500 BTU LP (4.0 kW)
One griddle 15,000 BTU Nat. (4.4 kW)/
13,500 BTU LP (4.0 kW)
One grill 18,000 BTU Nat. (5.3 kW)/
Preheat Rating 16,000 BTU LP (4.7 kW)
Preheat rating 240V—6,000 watts 240V—6,460 watts 240V—6,460 watts 240V—6,460 watts
208V—4,530 watts 208V—4,850 watts 208V—4,850 watts 208V—4,850 watts
Broil burner rating
Maxi-Broil—8-pass 240V—3,000 watts
208V—2,250 watts
Mini-Broil—4-pass 240V—1,250 watts
208V—940 watts
Bake burner rating 240V—2,935 watts 240V—3,440 watts 240V—3,440 watts 240V—3,440 watts
(partial power from broil element) 208V—2,247 watts 208V—2,620 watts 208V—2,620 watts 208V—2,620 watts
TruConvec rating 240V—2,200 watts
208V—1,650 watts
COOKING
Professional Freestanding Dual Fuel Self-Clean 30”/36”W.
Sealed Burner Range
Installation Requirements
ACCESS REQUIREMENTS
UTILITY
REQUIREMENTS
GAS
Shipped natural gas standard; field
convert to LP/propane with optional
accessory kit or order as LP by
adding LP after color code
• Accepts standard residential 1/2" ID
gas service line
• Gas manifold pressure
o Natural gas 5.0" W.C.P.
o LP/Propane 10.0" W.C.P.
ELECTRICAL
Electrical connection box on
product for hardwire direct; connect
with locally supplied, flexible cord
rated 40 amp; 125/250V min.; must
be agency-approved for use with
household electric ranges. It should
be fused separately.
Check your national and local codes
regarding this unit.
Maximum amp usage—
240 - 208/120 VAC/60 Hz
o 4B
240V—6098 watts; 25.4 amps
208V—4757 watts; 22.9 amps
o6B
240V—6634 watts; 27.6 amps
208V—5163 watts; 24.8 amps
o4G
240V—7462 watts; 31.1 amps
208V—5880 watts; 28.3 amps
o 4Q
240V—6634 watts; 27.6 amps
208V—5163 watts; 24.8 amps
PLUMBING
Not applicable