Viking VDSC530-4B Range User Manual


 
UTILITY
R
EQUIREMENTS
GAS
Shipped natural gas standard;
field
c
onvert to LP/propane with optional
a
ccessory kit or order as LP by
a
dding LP after color code
Gas manifold pressure
o
Natural gas 5.0” W.C.P.
o
LP/Propane 10.0” W.C.P.
ELECTRICAL
2
40-208 VAC, 60 Hz electrical
c
onnection box on product, connect
w
ith locally supplied 3-wire, flexible
cord or “pigtail” rated 40 amp 125-
250 VAC minimum. Cord must be
agency approved for use with
h
ousehold electric ranges.
Maximum amp usage—
2
40 - 208/120 VAC/60 Hz
o 4B
240V—6098 watts; 25.4 amps
208V—4757 watts; 22.9 amps
PLUMBING
N
ot applicable
COOKING
Professional Custom Series Freestanding Dual Fuel
Self-Clean 30”W. Sealed Burner Range
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM 1-888-VIKING1
RELEASED 8/6/08
©2008 VRC—INFORMATION SUBJECT TO CHANGE
VDSC530-4B
Surface burner rating
Left front grated burner 15,000 BTU Nat. (4.4 kW)/13,500 BTU LP (4.0 kW)
Left rear grated burner 15,000 BTU Nat. (4.4 kW)/13,500 BTU LP (4.0 kW)
Right front grated burner 15,000 BTU Nat. (4.4 kW)/13,500 BTU LP (4.0 kW)
Right rear grated burner 15,000 BTU Nat. (4.4 kW)/13,500 BTU LP (4.0 kW)
Installation Requirements
ACCESS REQUIREMENTS
2”
(5.1 cm)
Dia.
2-3/4”
(7.0 cm)
4-3/8”
(11.1 cm)
2-1/2”
(6.4 cm)
1-3/4”
(4.4 cm)
31-1/16”
(78.9 cm)
28-5/16”
(71.9 cm)
23-7/16”
(59.5 cm)
Gas or Electrical
connection in
this area
Gas connection
in this area