Viking VECU Cooktop User Manual


 
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
RELEASED 12/1/07
©2007 VRC—INFORMATION SUBJECT TO CHANGE
COOKING
Professional Built-In Electric Radiant
30”/36”W. Glass Ceramic Cooktop
18” min.
(45.7 cm)
6” min.
(15.2 cm)
3-1/8”
(7.9 cm)
0” min.
(
0 cm)
36” min.
(91.4 cm)
36” min.
(91.4 cm)
13” max.
(33.0 cm)
Minimum clearances from adjacent
combustible construction
Above countertop (36" [91.4 cm])
Sides—6” (15.2 cm)
Rear—0” (0 cm)
Within 8” (20.3 cm) side clearance; wall
cabinets no deeper than 13” (33.0 cm)
Must be minimum 18” (45.7 cm) above
countertop
Wall cabinets directly above cooktop
must be minimum 36” (91.4cm) above
the countertop.
1.The cooktop may be installed directly
to existing base cabinets.
2.The cooktop cannot be installed
directly adjacent to sidewalls, tall
cabinets, tall appliances, or other side
vertical surfaces above 36” (91.4 cm)
high. There must be a minimum of 6”
(15.2 cm) side clearance from the
cooktop to such combustible surfaces
above the 36” (91.4 cm) counter height.
3.Within the 6” (15.2 cm) side clearance
to combustible vertical surfaces above
36” (91.4 cm), the maximum wall
cabinet depth must be 13” (33.0 cm)
and wall cabinets within this 6”
(15.2 cm) side clearance must be 18”
(45.7 cm) above the 36” (91.4 cm) high
countertop.
4.Wall cabinet above the cooktop must
be a minimum of 36” (91.4 cm) above
the countertop for a full width of the
cooktop. This minimum height
requirement does not apply if a hood
is installed over the cooking surface.
5.A 120-volt wall receptacle should be
located approximately 6” (15.2 cm)
below the countertop cutout and 12”
(30.5 cm) from the right side of the
cutout.
The bottom of the hood should be 30”
(76.2 cm) min. to 36” (91.4 cm) above
the countertop. This would typically
result in the bottom of the hood being
66” (167.6 cm) to 72” (182.9 cm) above
the floor. Refer to the hood installation
instructions for further information.
Warning
The use of cabinets for storage above
the appliance may result in a potential
burn hazard. If a cabinet storage is to be
provided the risk can be reduced by
installing a hood that projects
horizontally a minimum of 5” (12.7 cm)
beyond the bottom of the cabinets.
Dimensions & Specifications
CLEARANCE DIMENSIONS