Viking VIPR102 Ventilation Hood User Manual


 
6
Downdraft VentilatorsVIKING RANGE, LLC
PREPARE THE DOWNDRAFT
Exterior Blower Installation
The downdraft is shipped without a blower. Purchase a Model
VEDV900 or VEDV1200 Exterior Blower and mount the 10"
discharge plate to the downdraft as follows:
1.
Place the downdraft on its back on a table of fl at work surface.
2. Remove the 4 nuts and 2 clamp channels.
3. Remove 2 screws and the gear motor cover.
4. Carefully position the10" discharge plate under the bottom
ange of the downdraft.
5. Connect motor plug.
6. Replace the gear motor cover and 2 sheet metal screws.
7. Replace the 2 clamp channels and start the 4 nuts, do not
tighten.
8. Slide blower left of right to desired position. Use cover plate
(supplied) to close up any open space.
9. Tighten 4 nuts to secure top of blower. Use additional screws
(supplied) through bottom fl ange to secure bottom of dis-
charge plate.
NUTS
COVER
PLATE
CLAMP
CHANNELS
SCREWS
GEARMOTOR
COVER
MOTOR
PLUG
10" ROUND
DISCHARGE
PLATE
ADDITIONAL
SCREWS
BOTTOM
FLANGE