Vinotemp VINO8500SSH Refrigerator User Manual


 
- 19 -
2. The value of the set point will be displayed and the “°C” or “°F” LED starts
blinking;
3. To change the Set value, push the o or n arrows within 10s.
4. To memorize the new set point value, push the SET key again or wait 10s.
4) Humidity Adjustment
The parameter Fon is used to adjust the humidity in the wine cabinet. The higher
value of Fon, the higher relative humidity will be.
1. Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.
2. Release the keys, then push again the Set + keys for more than 7sec, the
Pr2 label will be displayed.
3. Release the keys, select the required parameter Fon by up or down keys .
4. Press the “SET” key to display its value.
5. Use up or down keys
to change its value.
6. The default value is 0, change high or low value to maintain high or low
humidity.
7. Press “SET” to store the new value.
8. To exit: Press SET + or wait 15sec without pressing a key.
5) Regulation Differential
The parameter Hy is used as intervention differential for set point. Compressor
cut-in is the set-point + Hy, and compressor cut-out is the set-point.
1. Press the Set +
keys for 3 sec until the “°C” or “°F” LED starts blinking.
2. Release the keys, then push again the Set + keys for more than 7sec, the
Pr2 label will be displayed.
3. Release the keys, HY will display immediately.
4. Press the “SET” key to display its value.
5. Use up or down keys to change its value.
6. The default value is 4, change high or low value to result in long high or short
running cycle.
7. Press “SET” to store the new value.
8. To exit: Press SET + or wait 15sec without pressing a key.
6) Defrost Cycle
The parameter IdF is used as interval between defrost cycles.
1. Press the Set +
keys for 3 sec until the “°C” or “°F” LED starts blinking.
2. Release the keys, then push again the Set + keys for more than 7sec, the
Pr2 label will be displayed.
3. Release the keys, select the required parameter IdF by up or down keys
.
4. Press the “SET” key to display its value.
5. Use up or down keys to change its value.
6. 7. Press “SET” to store the new value.
8. To exit: Press SET +
or wait 15sec without pressing a key.
7) Manual Defrost
Push the DEF key for more than 2 seconds and a manual defrost will start.