- 7 -
Fig. 2.3 TOP EXHAUST GASKET
(LOCATED ON THE COOLING UNIT)
• Cut a rectangular inside opening at the rear of the cabinet with the 1/4”
clearance inwards to the width and height of the cooling unit. By not going
through, leave 1/2” lip inside at the wall to place the gaskets (see Fig. 2.2).
• If top exhaust, cut another rectangular opening at the top of the cabinet to
the length and width of the top exhaust (see Fig.2.2).
• Make 2 holes at the ceiling to install the 1/4 inside diameter wood thread
inserts (see Fig.2.2).
• Place the gaskets (1) on the gasket lips (see Fig 2.1).
• If top exhaust, place another gaskets along the top exhaust at the top of
the cooling unit (see Fig.2.3).
• Place the cooling unit to a flat and stable place.
• Then move it on the top of the wine rack temporally.
• Move the cooling unit towards the mounting sides and push to press the
gaskets.
• Fasten the 2 brackets and use 7/16” wrench to tighten the 2 screws (see
Fig 2.1).
• If top exhaust, install another top exhaust grille at the top of the cabinet.
• Plug the cooling unit in receptacle.
• Plug the wine cabinet.
NOTE: DO NOT INSTALL ANY DUCTS ONTO THE SUPPLY, INTAKE ANY
EXHAUST.
3. Electrical Cord
• Because of potential safety hazards under a certain condition, we strongly
recommend against the use of an extension cord. However, if you still
elect to use an extension cord, it is absolutely necessary that it will be a
UL LISTED 3-wire grounding type appliance extension cord having a 3-
blade grounding plug and a 3-slot receptacle that will plug into the
appliance. The marked rating of the extension cord shall be 115 V, 15 A.