Vinothèque GCM-01 030110 Refrigerator User Manual


 
Customer Service - 1.800.343.9463 Page 8
WHISPERKOOL SERIES ADVANCED CONTROLLER
Button Functions
ON/OFF • The ON/OFF button turns the refrigeration system on or o. This feature does not
disconnect power from the unit. The condenser fan will continue to run in the OFF position.
In order for the power to be shut o from the unit, the power cord must be unplugged from
the wall.
Up and Down
buttons
• Use these buttons to scroll through the control panel menu.
• These also display the highest and lowest temperature sensed by the bottle probe. This
feature allows the customer instant access to the recorded data applicable to the bottle
probe temperatures, it can be easily reset to reect current temperatures.
1. Press the “Up” arrow, or the “Down” arrow once, and the highest or lowest temperature
(Hi/Lo) sensed by the bottle probe, will be displayed.
2. To reset the Hi/Low, press and hold the “Set” button when the Hi/Low value is displayed
on the digital display, continue to hold the “Set” button until “RST” appears on the digital
display and then blinks. This will erase the past recorded temperature data history and start
recording, from the current time and temperature, forward. Temperatures displayed would
reect bottle probe temperatures from that point in time and beyond.
3. The Hi/Low feature should be reset at initial start-up and after the cellar or cabinet has
obtained normal operating temperatures — generally 55°F.
Cellar Pre-Chill • Activate the Cellar Pre-Chill feature by pressing the “Up” button for 3 to 5 seconds, and
the CPC logo (a yelowsnowake inside a semicircle) will be displayed on the digital display.
Terminate the CPC by pressing the “Up” button again for 3 to 5 seconds or the feature will
self-terminate after 6 hours.
1. The CPC feature may be used to pre-chill the cellar prior to loading it with warm bottles.
The feature will shift the set point down to a lower setting of 52°F, for the next 6 hours. After
the 6-hour time period, the set point will automatically return to the original set point.
Compressor
Evaporator Fan
Defrost
Energy Reduction
Button 1
Energy Reduction
Set Button
- View set point 1
- Change set point 3-5
- SET + Down = CPSM 5-7
- Reset Hi & Lo Button 3-5
Alarm
Pre-Chill Display
Condenser Fan
Cellar Pre-Chill Button 3-5
High Bottle Temp
History & Scroll Button 1
Low Bottle Temp History
& Scroll Button 1
“ON/OFF” button 1