1G4BD SERIES
FREE STANDING GAS FRYER
IMPORTANT
1. A combination valve with pressure regulator is provided with
this unit.
Natural Gas 4.0" (102 mm) W.C.
Propane Gas 10.0" (254 mm) W.C.
2. An adequate ventilation system is required for Commercial
Cooking Equipment. Information may be obtained by writing
to the National Fire Protection Association, Batterymarch
Park, Quincy, MA 02269. When writing refer to NFPA No. 96.
3. All models require a 6" (152 mm) clearance at both sides and
rear adjacent to combustible construction.
OVERALL WORKING TANK FRY COMP. APPROX.
MODEL WIDTH DEPTH HEIGHT HEIGHT SIZE BTU/HR. CAPACITY SHP.WT.
1G4BD 15
1
/
2
"30
1
/
4
"47
1
/
8
"36
1
/
4
" 14" x 14" 120,000 45 - 50 lbs. 215 lbs.
4. All models require a 16" (407 mm) minimum clearance to
adjacent open top burner units.
5. This appliance is manufactured for commercial installation
only and is not intended for home use.
SERVICE CONNECTIONS:
P1
1
/2" (13 mm) rear gas connection (single units).
E1 115 volt cord & 5-15P NEMA plug supplied with fryers.