Vulcan-Hart 1G6BD Fryer User Manual


 
GBD_GBDF SERIES GAS FRYERS
VULCAN-HART F-32934 Rev. B (June 2008)
-23-
Quick Start Guide for Solid State Knob Controls with KleenScreen PLUS® Filtration:
Filtering in 6 Easy Steps:
Step 1:
Make sure that the power is on. Do NOT turn
off the power to the fryer.
Step 2:
Open the drain valve slowly allowing the oil to
drain down into the filter pan. The burners will
automatically turn off.
Step 3:
Press FILTER switch to engage the motor / pump.
Allow the oil to cycle for a few minutes until the oil
and fryer are clean. TIP: Use the provided tank
brush to clean and remove food particles from the fry
tank.
Step 4:
Close the drain valve slowly allowing the oil to Drain Valve
fill the fry tank with clean oil. The burners will
not turn on at this point. Allow the oil to fill back
into the fry tank from the filter pan. It is normal to
see a few air bubbles during this process.
Step 5:
When the filter pan is empty push the FILTER switch
to turn off the motor / pump. Oil level should be
between the MIN and MAX lines.
Step 6:
Once the level of the oil has been checked and
verified, press the START switch. The burners will
automatically turn back on and the fryer will resume heating.