Vulcan-Hart 1GR45D Fryer User Manual


 
GRDF / GRCF SERIES GAS FRYERS
VULCAN-HART F-31214 Rev. D (March 2008)
-21-
INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS® FILTER ENVELOPE
FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RATE WE RECOMMEND YOU CHANGE YOUR FILTER
ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE).
Step 1
Discard all oil from the filter vessel, (see pages 23 or 24). When the
filter pan is empty, use a spatula and scrape off all debris left on the
filter envelope and in the filter pan.
Step 2
Unscrew “S” Tube from filter by turning the Bottom Knurled fitting
counter- clockwise.
Step 3
Remove SST Closure Clip by lifting off one side.
Step 4
Remove SST Filter Screen Insert and wash insert with hot water and
dry thoroughly. The Filter Screen Insert is dishwasher safe. Place the
insert into a new KleenScreen PLUS® Filter envelope.
DO NOT WASH FABRIC ENVELOPE
Step 5
Place Filter Screen Insert into the fabric envelope making sure that the
holes line up. Fold over the other end of the envelope and place SST
Closure Clip on – hinge over and firmly press clip all the way down to
secure and seal filter assembly. Making sure that the folded end is face
down; screw “S” Tube Assembly onto the Filter Assembly. Tighten the
Bottom Knurled fitting. When tightened, the “S” Tube assembly should
be perpendicular to the long side of the filter assembly.
Step 6
Reposition the filter tube into the provided clip. Align filter tube so that
the end of the “S” Tube engages the Oil Receptacle fitting each time the
drawer is opened and closed.