GRM SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. K (February 2011)
-6-
Minimum clearance from noncombustible construction:
0” from the sides of the fryer
0” from the back of the fryer
Between the fryer and any open-top flame units: 16” (41 cm)
Allow space for servicing and operation.
Location
Install fryer in an area with sufficient air supply for gas combustion at fryer burners.
Do not obstruct the flow of combustion and ventilation air.
Provide adequate clearance for air openings into the combustion chamber.
Do not permit fans to blow directly onto fryer.
Avoid wall-type fans, which create cross-currents within a room. Avoid open
windows next to sides or back.
CODES AND STANDARDS
The fryer must be installed in accordance with:
In the United States:
State and local codes, or in the absence of local codes, with:
National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may
be obtained from The American Gas Association Accredited Standards
Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the
Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-
7471.
NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition,
available from the National Fire Protection Association, Batterymarch Park,
Quincy, MA.
In the commonwealth of Massachusetts all gas appliances vented through a
ventilation hood or exhaust system with a damper or with a power means of
exhaust shall comply with 248 CMR.
In Canada:
Local codes
CAN/CSA-B149.1 Natural Gas and Propane Code Installation (latest edition),
available from the Canadian Gas Association 350 Sparks Street, Ottawa,
Ontario Canada K1R 7S8.
CSA C22.1 Canadian Electric Code L4W 5N6.