Vulcan-Hart 1GR45MF ML-136785 Fryer User Manual


 
GRM SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. K (February 2011)
-22-
FLUSH AND DISCARD:
1. Follow filtering instructions 1-3, however do not put oil treatment media into the fryer. Drain
the fryer oil into the filter pan.
2. Attach the quick disconnect hose to the discard male quick disconnect fitting.
3. Place other end of the discard hose into a container that is large enough to retain the
discarded shortening.
4. To start the discard operation, turn Power Switch ON.
5. Pull the Yellow Discard Handle Lever Rod towards you and the Motor/Pump will begin to
operate. NOTE: Oil will come out immediately out of the nozzle end of the hose.
6. Once the oil has been discarded completely and the filter pan is empty, push the Discard
Lever back in. The Motor/Pump will stop and turn the Power Switch OFF.
7. Disconnect the discard hose. Be careful to let the hose drain before putting away. Close the
drain valve and fill the fry tank with new oil.
BOIL OUT PROCEDURE:
Use the Boil Out By-Pass™ drain extension allowing the boil
out solution to exit the fry tank without using the filtering
system. Do NOT allow water to run through the motor / pump.
Drain the boil out solution into a bucket or place a high
temperature rated water hose on the end of the drain extension
allowing the other end to flow into a floor drain. In Fig. 6 the
arrow is pointing to the drain extension. It is threaded into the
top coupling of the oil drain tube. Drain extension needs to be
only hand tightened.
Fig. 6