Vulcan-Hart 1GR35M Fryer User Manual


 
GRM SERIES GAS FRYERS
VULCAN-HART F-31233 Rev. F (January 2008)
-11-
LIGHTING THE PILOT
A
B
A Thermostat Knob
B Gas Control Handle
1. Open the door.
2. Turn the thermostat to OFF (see figure below, view A). The thermostat is located
behind the door.
3. Push the gas control valve knob and turn to OFF. Wait 5 minutes for unburned gas
to vent.
4. Push and turn gas control valve knob to the “L” in PILOT (see figure below, view B).
5. While still holding the knob in, light the pilot with a lit flame. Continue to depress
the knob until pilot remains lit when knob is released. If the pilot does not remain lit,
repeat step 3 through 5.
6. Depress and turn gas control knob to ON (See figure below, view C).
7. If gas supply is interrupted, repeat steps 2 through 6.