Vulcan-Hart 60L77R Range User Manual


 
– 4 –
ECONOLINE SERVICE AND PARTS
WARNING: THE RANGE AND ITS PARTS ARE HOT.
BE VERY CAREFUL WHEN OPERATING, CLEANING
OR SERVICING THE RANGE.
CONTROLS (FIG. 1)
Thermostat Dial — allows operator to regulate oven
temperature from low to 500°F.
Open Top Burner Valve Knob — regulates gas flow to
top burners. Flame increases by turning knob counter-
clockwise, and decreases by turning knob clockwise.
Griddle Burner Valve Knob — regulates gas flow to
griddle burner. Heat increases by turning knob counter-
clockwise, and decreases by turning knob clockwise.
Nightly Shutdown: Turn oven thermostat OFF.
Extended Shutdown:
1. Turn oven thermostat OFF.
2. Turn main gas supply OFF.
Fig. 1
Fig. 2
SERVICE
LIGHTING AND SHUTTING DOWN PILOTS
NOTE: All adjustment procedures associated with pilot
lighting must be performed by a qualified Vulcan-Hart
installation or service person.
Oven Pilot
1. Turn main gas supply ON. Remove lower front panel
and lift lighting hole cover.
2. Depress the reset button located behind the lower
front panel and light with a lit taper (Fig. 2). Continue
to hold reset button for 1 minute.
3. If pilot fails to light, turn main gas supply OFF and wait
5 minutes before repeating Steps 1 and 2.
4. After pilot is lit, turn the thermostat dial to the desired
setting.