INSTALLATION
UNPACKING
Immediately after unpacking, check for possible shipping damage. If the oven is found to be damaged,
save the packaging material and contact the carrier within 15 days of delivery.
There may be a large label located on the front of the oven which reads, "Remove this label before
operation." To remove label, peel corner edges and slowly pull label off. If resistance is met, spray
area with WD-40, wait several minutes, then slowly remove label.
Before installing, verify that the type of gas supply (natural or propane) and electrical service (if
applicable) agree with the specifications on the rating plate located on the control panel of the oven.
If the supply and equipment requirements do not agree, contact your dealer or Vulcan-Hart immediately.
LOCATION
The equipment area must be kept free and clear of combustible substances. The oven, when installed,
must have minimum clearance from combustible construction of 0" from the sides and 6" from the rear;
minimum clearance from non-combustible construction is 0" from the sides and 0" from the rear.
The installation location must allow adequate clearances for servicing and proper operation. A
minimum front clearance of 36" is required.
The oven must be installed so that the flow of combustion and ventilation air will not be obstructed.
Adequate clearance for air openings into the combustion chamber must be provided. Make sure there
is an adequate supply of air in the room suitable for the amount of combustion gas feeding the oven
burners.
Do not permit fans to blow directly at the oven. Avoid open windows next to the oven. Avoid wall-type
fans which create air cross currents within the room.
INSTALLATION CODES AND STANDARDS
Your Vulcan 7000 Series Bake/Roast Oven must be installed in accordance with:
1. State and local codes, or in the absence of local codes, with:
2. National Fuel Gas Code, ANSI-Z223.1 (latest edition), available from the American Gas Association,
Inc., 1515 Wilson Blvd., Arlington, VA 22209.
3. National Electrical Code ANSI/NFPA-70 (latest edition).