Vulcan-Hart AGM36 Griddle User Manual


 
-
11 -
CONTROLS – AGM MODELS
The model is equipped with standing pilots. Gas will flow from the pilots as soon as the
main gas supply to the unit is turned on. The pilots are lit with the use of an outside
ignition source (such as a lit taper, etc). There is one pilot for every two burners except
on the 36” and 60” models. The 36” and 60” models have an odd number of main
burners; therefore one of the sets of pilots in these models will control only one main
burner. The pilots are inset 12” from the front panel. See pilot lighting procedure.
Each 12” section of the griddle is independently controlled by an infinite heat control
valve. Once the pilots are lit, turning the burner control knob to the full ON position will
light each burner. The burners will be in the full ON position when the knobs are turned
all the way to the left (Fig. 10). The burners will be in the full OFF position when the
knobs are turned all the way to the right (Fig. 9). The height of the burner flame and
cooking plate temperature can be adjusted by turning the burner control knobs while
viewing burners through the burner sight holes.
burner control
knob
pilot ad
j
ustment screw
Fig. 9
Fig. 8
Burner control knob in the OFF position.
Turned all the way to the right.
Burner control knob in the full ON
position. Turned all the way to the left -
225 degrees from the OFF position.
Fig. 10
burner and pilot sight
holes