Vulcan-Hart C60CS Range User Manual


 
7. Open oven door and remove oven racks.
8. Remove screws securing capillary tube mounting
clips (5) inside the oven cavity.
Fig. 15
NOTE: Capillary tube is permanently attached to
thermostat-combo valve.
9. Remove all mounting clips from capillary tube
and retain for reuse.
10. Pull capillary tube through the hole in oven
sidewall and remove thermostat from oven.
A. Remove insulation sleeve from capillary
tube for installation on replacement
thermostat capillary tube.
B. Note orientation of compression fitting
elbow on valve body and remove for
installation on replacement valve body.
Clean pipe threads and apply thread
sealant that is suitable for use with propane gases.
When installing, do not bend and kink the
capillary tube or damage to the control may occur.
11. Reverse procedure to install and check for proper
operation.
STANDARD OVEN THERMOSTAT
(30" OVEN)
Shut off the gas before servicing the
unit.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1. Open oven door and remove oven racks.
2. Remove screws securing capillary tube mounting
clips (5) inside the oven cavity.
Standard 30" oven
NOTE: Capillary tube is permanently attached to
thermostat.
3. Remove all mounting clips from capillary tube
and retain for reuse.
4. Remove CONTROL PANEL (30" OVENS).
5. Remove compression nuts from thermostat
fittings (front & rear).
6. Remove screws securing thermostat to mounting
bracket.
Fig. 17
ENDURANCE / CHALLENGER MODULAR SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS
F45471 Rev. A (0615) Page 10 of 38