Vulcan-Hart E36LC Range User Manual


 
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and 
specifications without notice.
Printed On Recycled Paper
3.00 (76MM)
WITH GRIDDLE
(GREASE COLLECTOR)
26.250
(667MM)
22.750
(578MM)
59.500
(1511MM)
30.000
(762MM)
12.000
(305MM)
2.000
(51MM)
.500
(13MM)
6.00 (152)
10.75 (273)
28.500
(724MM)
31.875
(810MM)
19.500
(495MM)
13.620
(368MM)
ELECTRICAL CONNECTION
30.500
(775MM)
6.000 MIN.
(152MM)
8.000 MAX.
(203MM)
23.000
(584MM)
MOTOR
E36LC
UNITS ONLY
6.000
(152MM)
TYP.
6.000
(152MM)
TYP.
12.000
(305MM)
TYP.
12.000
(305MM)
TYP.
36.000
(914MM)
F-32153 (11/07)
E36LC SERIES
ELECTRIC RANGES
This appliance is manufactured for commercial installation
only and not intended for domestic/household installation.
CLEARANCES FROM COMBUSTIBLE CONSTRUCTION:
Range only ...............................................0" sides, 0" rear
Clearance Note: Electric  Ranges  0  inches  sides  and 
rear  from  combustible  and  non-combustible  construction 
except when hot top sections are incorporated. Ranges 
incorporating 
hot top sections are 0 inches sides and rear to 
non-combustible  and 
6" sides and rear to combustible
construction.
AVAILABLE VOLTAGES - 208 OR 240 VOLT - 1 OR 3-PHASE, 480 VOLT - 3-PHASE
3-PHASE LOADING NOMINAL AMPS PER LINE WIRE
MODEL
NO.
TOTAL
CONN.
kW
kW PER PHASE
3-PHASE
1-PHASE
208V 240V 480V
X-Y Y-Z
X-Z X Y Z X Y Z X Y Z 208V 240V 480V
E36LC
17.2 4.0 8.0 5.2 38.3 50.0 54.9 33.2 43.3 47.6 16.5 21.6 23.7 82.6 71.6 n/a
E36SLC
16.6 4.0 7.4 5.2 38.3 47.5 52.4 33.2 41.1 45.4 16.5 20.8 22.6 79.7 69.1 n/a
E36FLC
16.0 4.0 6.8 5.2 38.3 45.0 49.9 33.2 39.0 43.3 16.5 19.7 21.5 76.9 66.6 n/a
E36XLC
15.4 3.4 6.8 5.2 35.8 42.5 49.9 31.0 36.8 43.3 n/a n/a n/a 74.0 64.1 n/a