Vulcan-Hart ECO2D ML-114570 Convection Oven User Manual


 
– 11 –
BEFORE FIRST USE
Before using the oven for the first time, it must be "burned in" to release any odors that might result from
heating the new surfaces in the chamber.
1. Using a clean damp cloth, wipe the inside of the oven, including the racks.
2. Close the oven door, push the ON / OFF / OVEN COOL switch ON, turn the Thermostat to 300°F
(149°C) and allow the oven to cycle for 6 to 8 hours before turning the ON / OFF / OVEN COOL
switch OFF.
USING THE ECO2C OVEN
Preheating
1. Close oven door. Push ON / OFF / OVEN COOL switch ON. The HEAT light will come on,
indicating that power to the oven is on.
2. Set THERMOSTAT as desired. Refer to SUGGESTED COOKING GUIDELINES for temperatures
and times.
3. Prepare product and place in suitable pans. When READY light comes on, oven has reached
desired preheat temperature.
Roasting
1. Open the door and load the product into the oven. Place pans in the center of racks. Close the
door.
2. Set ROAST temperature and time. Set HOLD temperature and GENTLE BAKE time, if desired.
GENTLE BAKE time cannot be more than ROAST time. GENTLE BAKE will cycle the fan during
the set time at the beginning of the cooking cycle.
3. Press the START / STOP button to start the cooking cycle.
4. At the end of the cooking cycle, the alarm will sound continuously if the HOLD mode is OFF. If
the HOLD mode is ON, there will be a short beep at the beginning of Second Stage Cooking (oven
temperature will begin to decline to the HOLD temperature), and a long beep (20 seconds) at the
end of the cooking cycle. Refer to ROAST AND HOLD OPERATION.
5. When product is done, open the door and carefully remove cooked product from the oven. Wipe
up any spills.
End of Day
1. Push ON / OFF / OVEN COOL switch to OVEN COOL. Leave door ajar while the fan is on to cool
the oven.
2. When the oven has cooled sufficiently, push the ON / OFF / OVEN COOL switch to the OFF
position and clean the oven.
ERROR MESSAGES — Model ECO2C
E-01 High limit error. Contact Vulcan authorized service.
E-02 Low limit error. Contact Vulcan authorized service.
E-03 High ambient temperature, 215°F
(102°C). Contact Vulcan authorized service.
E-04 Low ambient temperature, 32°F
(0°C). Let control warm up after cold storage.
E-06 Thermocouple probe open. Contact Vulcan authorized service.
When calling for service, please advise what error code was displayed.