Vulcan-Hart ECO6C ML-52505 Convection Oven User Manual


 
– 7 –
Electrical Connections
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE
PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
Ensure that the electrical power supply agrees with the specifications on the oven data plate and complies with
the wiring diagram on the oven.
1. Attach the power leads (furnished as part of the stack set) to the line side of the terminal block of the upper
oven. Then carefully route these leads down through the conduit nipple and behind the control panel of the
lower oven.
2. Attach these leads to the lower oven terminal block per the wiring diagram. At the same time, attach the
power supply conduit to the bottom of the lower oven. Also attach the power supply leads to the line side
of the terminal block.
3. Finally, inspect and check all wiring and terminal connections for tightness and proper routing away from any
moving parts (relay solenoid core), or pinch points (cover on oven frame). Then carefully replace the oven
control panel for both ovens.
Refer to Electrical Data chart on page 5.
LEVELING
Adjust the legs to ensure that the oven racks are level in the final installed position by turning the bottom hex
tips on the floor.
CASTERS
If the stacked ovens are to be installed on casters, assemble the casters to the legs provided. Place the locking
casters on the front legs and non-locking casters on the rear legs.