Vulcan-Hart GCO4C ML-52357 Oven User Manual


 
8
ASSEMBLING THE OVEN TO THE STAND
Unpack the oven and stand. Position oven on its back, taking care not to scratch or damage it. The gas pipe
connection protrudes beyond the back; provide for this when the oven is tipped back by resting it on suitable
spacers (2 x 4's, etc.).
Install the two locating studs (included in the stand carton) into the screw plates on the underside of the oven
(see Fig. 2).
Attach each of the four leg assemblies to the bottom of the stand with the 24 bolts and lockwashers (6 per leg).
Mount the oven on top of the stand.
ELECTRICAL CONNECTIONS
WARNING: THE POWER SUPPLY CORD IS PROVIDED WITH A GROUNDING PLUG. THE OUTLET TO
WHICH THIS PLUG IS CONNECTED MUST BE PROPERLY GROUNDED. IF THE RECEPTACLE IS NOT THE
PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN.
The Model GCO Series Gas Convection Ovens are equipped with a 120 volt / 60 Hz. / 1 phase cord and plug.
A wiring diagram is located on the inside of the right side panel.
GAS AND ELECTRICAL DATA
GAS DATA ELECTRICAL DATA
MODEL INPUT BTU/HR MANIFOLD PRESSURE AMP LINE
Natural Propane Natural Propane 120 Volts
GCO4S
GCO4D/GCO6D 40,000 40,000 3.5" W.C. 10" W.C. 10 Amps
GCO4C/GCO6C (0.8 kPa)
GCO44S
GCO44D/66D 80,000 80,000 3.5" W.C. 10" W.C. 20 Amps
GCO44C/66C (0.8 kPa)
GAS CONNECTIONS
Gas supply connections and pipe joint compound must be suitable for sealing piping for propane or natural
gases.
The oven is provided with a regulator integral to the gas solenoid valve and requires no external regulator.
The manual gas shutoff valve is located at the bottom of the front control panel.