Vulcan-Hart GL80E ML-52637 Hot Beverage Maker User Manual


 
– 8 –
CONTROLS — KETTLES WITH ELECTRONIC IGNITION (Prior Construction, Fig. 2)
Thermostat Controls heat in the kettle. High dial settings are for cooking; low
settings are for holding.
On – Off Switch Located on the upper right-hand corner of the control panel.
When turned to ON, initiates the electronic ignition system.
Combination Control Valve Controls gas flow to the main burner. The valve has a built in
gas pressure regulator which shuts off all gas in the event of pilot
outage.
Pressure Gauge Indicates pressure in the jacket, normal operating range is 0 to
12 psig.
Fig. 2 Fig. 3
CONTROLS — KETTLES WITH MANUAL PILOT BURNER (Prior Construction, Fig. 3)
Thermostat Controls heat in the kettle. High dial settings are for cooking; low
settings are for holding.
Combination Control Valve Controls gas flow to the main burner. The valve has a built in
gas pressure regulator which shuts off all gas in the event of pilot
outage.
Pressure Gauge Indicates pressure in the jacket, normal operating range is 0 to
12 psig.
OFF
THERMOSTAT
PRESSURE GAUGE
ON – OFF SWITCH
LID
KETTLE
JACKET
JACKET WATER LEVEL
COMBINATION
CONTROL VALVE
(Built before September 2003)
OFF
PRESSURE GAUGE
LID
KETTLE
JACKET
JACKET WATER LEVEL
COMBINATION
CONTROL VALVE
(Built before November 2002)
THERMOSTAT