Vulcan-Hart GTS12-4R Cooktop User Manual


 
-
17 -
ELECTRICAL CONNECTIONS
Electrical and grounding connections must comply with the
applicable portions of the National Electrical Code and/or other local electrical
codes.
Disconnect the electrical power to the griddle and follow lockout /
tagout procedures.
Since the griddle top is not fused, you must connect to a fused circuit equipped with a
suitable disconnecting means as required by local authorities.
Electrical Connections
1. Remove the small junction box cover plate on the back of the unit. This exposes the
GTS clamshell griddle line leads.
2. Select a suitable knockout on the sides or bottom of the junction box.
3. Connect the griddle’s line leads to the supply wires with factory supplied wire connectors as shown
in the applicable wiring diagrams.
4. Push the excess wire into the junction box and replace the cover plate. Never operate griddle
without cover in place.
ELECTRICALSPECIFICATIONS
ModelNo Description Voltage Power
1Phase
Draw
GTS121
FrontGrease
TroughModels
208V 3.6kW 17.3A
GTS122 240V 3.6kW 15A
GTS123R
RearGrease
TroughModels
208V 3.6kW 17.3A
GTS124R 240V 3.6kW 15A