Vulcan-Hart K40EL ML-136074 Hot Beverage Maker User Manual


 
Fig. 11
NOTE: If liquid drained from kettle is still clean, save
for reuse.
5. Remove heater access cover.
Fig. 12
6. Note lead wire locations and disconnect wires
from heating element.
7. Remove mounting bolts securing heating
element to kettle.
Fig. 13
8. Remove heating element from kettle.
9. Reverse procedure to install. Use a new heating
element seal whenever installing heating
element. Torque mounting nuts to 40 ft-lbs and
tighten in an alternating pattern.
10. Refill jacket with fluid. See FILLING THE
RESERVOIR JACKET.
11. Remove air from reservoir jacket as outlined
under VENTING.
12. Check for proper operation and leaks around
heating element.
STATIONARY KETTLE
1. Open pressure relief valve until reservoir jacket
is completely vented.
2. Remove BOTTOM COVER.
3. Remove wire from Water Level Probe (LLCO).
4. Place a large container under the kettle. Remove
water level probe (LLCO) and open the fill valve
(40 & 60 gallon kettles) or remove pipe plug from
fill elbow (20 gallon kettles) to vent the jacket and
drain liquid from kettle.
Electric Stationary and Tilting Kettles - REMOVAL AND REPLACEMENT OF PARTS
F45472 (1112) Page 8 of 29