Vulcan-Hart K40GL Hot Beverage Maker User Manual


 
14
GAS KETTLES
VENTING
While the kettle is cold, check the vacuum/pressure gauge. The gauge should be in the vacuum zone
measuring between 20 to 30 in. Hg (84 to 100kPa). If not, there is air in the jacket and it must be
removed by venting for proper heating. Perform the venting procedure located in the Maintenance
section of this manual.
RESERVOIR JACKET WATER LEVEL CHECK
During use, the reservoir water level must be maintained high to cover the entire heating zone. If the
low water light is illuminated during use, perform the Filling the Reservoir Jacket procedure located in
the Maintenance section of this manual.
TILTING KETTLES
The low water indicator light (red) should not be lit when kettle is in upright position during operation.
This light indicates that the burner has been automatically shut off by the kettle’s safety circuitry. It
is, however, normal for the low water light (red light) to come on when the kettle is in a tilted position.
OPERATING DATA
MODEL NO. GALLONS OF WATER BURNER
INPUT
BTU/HR
HEAT UP TIME-MINUTES
WORKING
CAPACITY
JACKET
CHARGE
EMPTY
TO 5 PSI
2/3
FULL
130˚F
RISE
K20GLT/K20GLT 20 7 100,000 10 20
K40GLT/K40GLT 40 7 100,000 10 40
K60GL/K60GLT 60 8 100,000 15 60