Vulcan-Hart K60DLT Hot Beverage Maker User Manual


 
— 15 —
DIRECT STEAM KETTLES
MAINTENANCE
SERVICE
To obtain service and parts information concerning this unit, contact the Vulcan-Hart Service Agency
in your area (refer to listing supplied with the kettle), or contact the Vulcan-Hart Service Department
at the address or phone number shown on the front cover of this manual.
Parts and service are also available at www.vulcanequipment.com.
TROUBLESHOOTING
Problem Possible Causes / Suggested Corrective Action
Unit not Heating Verify incoming steam supply valve is open and pressure-
reducing valve is open.
Blocked/plugged steam trap of strainer. Contact building
maintenance or authorized service company.
Noisy (crackling) Will not harm the kettle. It is an indication that there is
condensate in the steam supply line and a steam trap
should be installed in the supply line before the kettle. Turn
kettle off and open drain valve on bottom of kettle to drain
water out. Close valve and turn on steam control valve.
Pressure relief valve leaking
steam
Incoming steam supply too high or faulty pressure relief
valve. Contact building maintenance or authorized service
company.