Vulcan-Hart MG60 ML-52524 Range User Manual


 
– 13 –
Nightly Shutdown: Turn burner valve OFF; pilot will remain lit.
Complete Shutdown
1. Turn burner valve OFF; pilot will remain lit.
2. Turn main gas supply OFF.
Open Top Burners
1. Turn main gas supply ON.
2. Turn all top burner valve knobs ON to purge gas line of air.
3. Turn top burner valve knobs OFF.
4. Wait 30 seconds.
5. Using a taper, light the open top pilot (Fig. 7).
Fig. 7
6. If pilot fails to light, wait 5 minutes and repeat Steps 1 thru 5.
7. Turn one open top burner valve ON to ensure that all gas lines are completely
purged of air. Turn burner OFF when gas begins to flow.
Nightly Shutdown: Turn burner valve OFF; pilot will remain lit.
Complete Shutdown
1. Turn burner valve OFF; pilot will remain lit.
2. Turn main gas supply OFF.