Vulcan-Hart ML-135341-00048 Griddle User Manual


 
-
14 -
PILOT
The RRG Series Griddles utilize a solenoid valve with
a brass pilot valve to control gas flow to pilot burners.
One to three pilot flames can be fed by one valve –
one leg of which may be branched.
PILOT TROUBLESHOOTING
SYMPTOM – PILOT WILL NOT LIGHT
1. Check pilot adjustment at solenoid valve
2. Check that power switch is on
3. Check that pilot solenoid valve is working
4. Check that safety ignition module and power switch are working
5. Check gas pressure
6. Check for air in the line
PILOT ASSEMBLY REMOVAL
Disconnect the electrical power and follow lockout / tagout procedures
Shut off gas supply
1. Remove control panel. Reaching
underneath the front of the unit,
remove the pilot tube fitting and
disengage the pilot tube from the pilot.
2. Reaching underneath the front of the
unit, remove the pilot bracket retaining
screw(#2 Phillips) and remove the
entire assembly out through the pilot
access cutout and out from under the
unit.
3. Disconnect the electrode wire from the
from the safety ignition module.
4. Remove the pilot from the bracket.
5. Reverse procedure to install
6. Verify gas pressure and check for
proper operation
All gas joints disturbed during servicing must be checked for leaks.
Check with a soap and water solution. Do not use an open flame.
BRASS PILOT
VALVE
BRACKET RETAINING SCREW
PILOT ASSEMBLY
ELECTRODE
PILOT
ACCESS
CUTOUT