Vulcan-Hart MSA60 ASA60 Griddle User Manual


 
-
14 -
PILOT LIGHTING PROCEDURE – AGM MODELS
1. Turn the main gas shut-off valve and all burner control knobs to the OFF position. Wait 5 minutes to
allow any gas that may have accumulated in the burner compartment to escape.
2. Turn the main gas shut-off valve ON.
3. While viewing through the pilot sight hole, you will have to reach under the front of the unit and through
the pilot cutout to ignite the pilots with an outside ignition source(such as a lit taper, etc.). It may be
necessary to adjust the pilot valve to increase gas to the pilot.
4. Repeat steps until all pilots are lit
5. To light main burners, turn individual burner control knobs to the full ON position.
6. If after completing steps 1-5 main burners do not light, turn off the main gas shut-off valve and
contact an authorized service agency.
CUTAWAY VIEW
Fig. 13
pilot burner
pilot cutout
pilot sight
hole
12”
burner control
knob