Vulcan-Hart MSA72 ASA72 Griddle User Manual


 
-
4 -
INSTALLATION, OPERATION AND CARE OF
HEAVY DUTY GAS GRIDDLES
GENERAL
Heavy Duty Gas Griddles are produced with quality workmanship and materials. Proper
installation, usage and maintenance of your griddle will result in many years of
satisfactory performance.
Thoroughly read this entire manual and carefully follow all of the instructions provided
Model Number of Burners
BTU/hr Input
Rating
924RX/MSA24/ASA24/AGM24 2 54,000
936RX/MSA36/ASA36/AGM36 3 81,000
948RX/MSA48/ASA48/AGM48 4 108,000
960RX/MSA60/ASA60/AGM60 5 135,000
972RX/MSA72/ASA72/AGM72 6 162,000
INSTALLATION
Before installing, verify that the type of gas supply (natural gas or propane) agrees with
the specifications on the rating plate located on the outside right of the unit. If the supply
and equipment requirements do not agree, do not proceed with the installation. Contact
your dealer immediately. It is recommended that a trained gas service technician with the
necessary tools, instruments and skills perform the installation of the griddle.
UNPACKING
This griddle was inspected before leaving the factory. The transportation company
assumes full responsibility for safe delivery upon acceptance of shipment. Check for
possible shipping damage immediately after unpacking. If the griddle is found to be
damaged, save the packaging material and contact the carrier within 15 days of delivery.
Carefully unpack your griddle and make sure that no parts are discarded with packaging
material. A pressure regulator designed to operate with the griddle has been supplied and
must be installed before the griddle is placed into service (Refer to GAS PRESSURE
REGULATOR INSTALLATION in this manual).
LOCATION
The installation location must be kept free and clear of combustibles. When installing,
never enclose the bottom of the griddle with a raised curb or other constructions that
would obstruct flow of air into or out of the griddle. Adequate clearance for air openings
into the combustion chamber must be provided. Make sure there is an adequate supply of
air in the room to replace air taken out by the ventilation system.