A pressure regulator sized for this unit is included. 1.
Natural gas 5.0” W.C., propane gas 10.0” W.C.
Gas line connecting to range must be 3/4” or larger. If 2.
exibleconnectorsareused,theinsidediametermustbe
3/4” or larger.
An adequate ventilation system is required for commercial 3.
cooking equipment. Information may be obtained by
writing to the National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02269, www.NFPA.org.
When writing, refer to NFPA No. 96.
These units are manufactured for installation in 4.
accordance with ANSZ223.1A (latest edition), National
Fuel Gas Code. Copies may be obtained from The
American Gas Association, 400 N Capitol St. NW,
Washington, DC 20001, www.AGA.org.
Clearances5. Rear Sides
Combustible 6” 10”
Standard Oven Non-combustible 0” 0”
Convection Oven Non-combustible Min. 4” 0”
For proper combustion, install equipment on adjustable 6.
legs or casters provided with unit.
For proper combustion, install equipment on adjustable 7.
legs or casters provided with unit.
NOTE: In line with its policy to continually improve its product,
Vulcanreservestherighttochangematerialsandspecications
without notice.
Specify type of gas when ordering. Specify altitude when
above 2,000 feet.
INSTALLATION INSTRUCTIONS
TOP
CONFIGURATION
MODEL
NUMBER
DESCRIPTION
TOTAL INPUT
BTU / HR
SHIPPING WEIGHT
LBS / KG
V24-1 4 Burners / 1 Standard Oven / Natural Gas 140,000 320 / 140
V24-2 4 Burners / 1 Standard Oven / Propane 140,000 320 / 140
.5
2
29.873
22.675
29.763
30.986
30.048
12
6
24
12.000
9.680
1.500
8.000 MAX
6.000 MIN
58
11.978
24” GAS RESTAURANT RANGE
4 OPEN BURNERS
VULCAN VALUE
SERIES
F-37396 (12/08)
Vulcan & Wolf Range
a division of ITW Food Equipment Group LLC
P.O. Box 696
n
Louisville, KY 40201
n
Toll-free: 1-800-814-2028
n
Local: 502-778-2791
n
Quote & Order Fax: 1-800-444-0602
This appliance is manufactured for commercial use only and is not intended for home use.