Vulcan-Hart VCCB36 Oven User Manual


 
LOCATION
The installation location must be kept free and clear of combustibles. Do not obstruct the
flow of combustion and ventilation air. DO NOT install the charbroiler adjacent to open
burners or fryers.
Sufficient air should be allowed to enter the room to compensate for the amount of air
removed by any ventilating system and for combustion of the gas burners. Do not
obstruct the air flow into and around the appliance. Do not obstruct the flow of flue gases
through and above the broiler's top grate. Position the broiler in its final location. Check
that there are sufficient clearances to service the broiler and to make the required gas
supply connection(s). Provide 24" clearance at the front for cleaning, maintenance,
service and proper operation.
Minimum clearances to combustible construction are 12" to the back and 9" to the sides.
Minimum clearances to non-combustible walls are 0" to the rear and 0" to the sides.
INSTALLATION CODES AND STANDARDS
The Charbroiler must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but
not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained
from The American Gas Association Accredited Standards Committee Z223, @ 400
N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA,
1 Batterymarch Park Quincy, MA 02169-7471
3. NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available
from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
In Canada:
1. Local codes.
2. CAN/CSA-B149.1 Natural Gas Installation (latest edition)
3. CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the
Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3
Burners
BURNERS, RADIANTS, AND TOP GRATES
The top grates are shipped flat (top-side
down) from the factory for stock pot use.
For broiling, the top grates should be
reversed so they slope forward for grease
run-off. Remove the cast iron radiants
(Fig. 1) and inspect and remove the
shipping tape used during shipping to hold
the burners in place. Reassemble the
radiants and the top grates.
Radiants
To
p
Grate
Fig. 1
- 4 -