Printed On Recycled Paper
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
F-32445 (10-03)
MODEL VCE6H
ELECTRIC COMBI OVEN
ACCESSORIES
■■ Stainless steel stand with (legs)/(casters).
■■ Pan slides for stand.
■■ Mobile landing table.
■■ Flexible water connection with (
3
/4" NSHT) - 2 required.
■■ Spray down hose with retaining hook, 118" long with
3
/4" NSHT.
■■ Pan rack assembly.
■■ Wire racks. Qty._____.
■■ Chicken rack. Qty._____.
■■ Stacking kit (legs)/(casters):
- Six half on six half.
- Six half on ten half (refer to VCE10H spec no. F32136).
- Six half on ten full (refer to VCE10F spec no. F32138).
■■ Additional pan rack insert. Qty._____.
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable
for steam generation. Your water supply must be within these general
guidelines:
SUPPLY PRESSURE 20 - 60 psig
HARDNESS* less than 3 grains
SILICA less than 13 ppm
TOTAL CHLORIDE less than 4.0 ppm
pH RANGE 7-8
UN-DISSOLVED SOLIDS less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of
chloridation and dissolved gases. Water supplies vary from state to state
and from locations within a state. Therefore it is necessary that the local
water treatment specialist be consulted before the installation of any
steam generating equipment.
CLEARANCES: 4" right 6" rear
SERVICE CONNECTIONS:
E Electric connection:
C1 Cold water connection:
3
/4" NSHT for generator feed. Inlet water
pressure between 20 and 60 psi.
C2 Cold water connection:
3
/4" NSHT for cold water condenser.
Inlet water pressure between 20 and 60 psi.
D Drain: Condensate box, ompartment and boiler 1
1
/2" NPT. (Provide
an open air type drain within 12" of condensate box and for best
results at a distance so that steam vapors will not enter the steamer
from underneath the control area. Do not connect solidly to any
drain connection.)
NOTE:
• Dimensions which locate the above connections have a tolerance of
+ or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other spe-
cific code requirements is the responsibility of the owner and installer.
It is the responsibility of the owner and installer to comply with local
codes.
• Plastic drains are not recommended due to inherent limited tempera-
tures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge
water temperature to be that of the condensate temperature of 140°F
or less.
• This appliance is manufactured for commercial installation only and is
not intended for home use.
PAN CAPACITY
STEAM TABLE PANS BAKE PANS
12" x 20" x 2
1
/2" 12" x 20" x 4" 18" x 13" 18" x 26"
636N/A
ELECTRICAL RATING
208V/60/3 240V/60/3 480V/60/3
KW AMP KW AMP KW AMP
926 922 911