MODEL VHX10G
GAS CONVECTION STEAMER ON CABINET BASE
SERVICE CONNECTIONS:
Unless otherwise specified, Field Wire Electrical Connection to
be 120/60/1 with grounding wire. Furnish with 6 foot cord with
3 prong plug. Maximum amps 2.0.
DRAIN: Condenser box, compartment and boiler, 2" NPT.
(Provide an open air gap type drain within 12" of condenser box
and for best results at a distance so steam vapors will not enter
the steamer from underneath the control area. Do not connect
solidly to any drain connection.)
GAS CONNECTION:
3
/4" (19 mm) O.D. supply line required.
GENERATOR WATER:
3
/8" (10 mm) O.D. tubing at 25-50 PSI
(170-345 kPa).
CONDENSING WATER:
3
/8" (10 mm) O.D. tubing at 25-50 PSI
(170-345 kPa).
IMPORTANT:
1. A combination valve with pressure regulator is provided with this unit.
Supply gas pressure should be a minimum: Natural gas 7"
W.C., propane gas 11" W.C.
2. Gas line connecting to unit must be
3
/4" or larger. If flexible connectors
are used, the inside diameter must be at least the same as the
3
/4"
iron pipe.
3. An adequate ventilation system is required for commercial cooking
equipment. Information may be obtained by writing to the National
Fire Protection Association, Batterymarch Park, Quincy, MA 02289.
When writing, refer to NFPA No. 96.
4. These units are manufactured for installation in accordance with
ANSZ223.1A (latest edition), National Fuel Gas Code. Copies may be
obtained from the American Gas Association, 1515 Wilson Blvd.,
Arlington, VA 22209.
5. Clearance: Combustible Non-Combustible
Rear 6" 0"
Left Side 0" 0"
Right side 0" 0"
NOTE:
Dimensions which locate the above connections have a tolerance of
+ or -3" (+ or -75 mm).
Installation of backflow preventers, vacuum breakers and other spe-
cific code requirements is the responsibility of the owner and installer.
It is the responsibility of the owner and installer to comply with local
codes.
Plastic drains are not recommended due to inherent limited tempera-
tures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge
water temperature to be that of the condensate temperature of 140°F
or less.
This appliance is manufactured for commercial installation only and is
not intended for home use.
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable for
steam generation. Your water supply must be within these general
guidelines:
SUPPLY PRESSURE 20 - 60 psig
HARDNESS* less than 3 grains
SILICA less than 13 ppm
TOTAL CHLORIDE less than 4.0 ppm
pH RANGE 7-8
UN-DISSOLVED SOLIDS less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of
chloridation and dissolved gases. Water supplies vary from state to state
and from locations within a state. Therefore it is necessary that the
local water treatment specialist be consulted before the installation of
any steam generating equipment