VHX SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS
F25154 (February 2004)Page 7 of 48
REMOVAL AND REPLACEMENT OF PARTS
PRESSURE SWITCH CONTROL
BOX COMPONENTS
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
CAUTION: Certain components in this system are subject to damage by electrostatic discharge during
field repairs. A field service grounding kit is available to prevent damage. The field service grounding kit
must be used anytime a control board is handled.
1. Open the cabinet base door.
2. Remove cover from pressure switch control box.
3. Disconnect lead wires from component being replaced.
4. To remove:
A. Cycling pressure switch.
1) Disconnect compression fittings in the pressure supply line leading to the switch.
2) Remove mounting nuts from pressure switch mounting panel.
3) Disconnect conduit from box.