WARMERS WITH MANIFOLDED DRAIN
1. Manifolded warmers have a single drain valve.
2. Water poured into any one section will seek the same water
level with all sections on the manifold.
3. Make sure the drain valve is fully closed before filling warmer.
AUTOFILL WARMERS
1. Autofill warmers sense water level by a sensor placed at the
proper level. For manifolded autofill warmers, the water level
sensor / fill tube is in one pan only, normally in the far left pan.
2. Water fills the pan through an inlet tube. For manifolded
autofill warmers, the fill tube is normally in the far left pan. All
other sections fill at the same time through the drain manifold.
3. The autofill function is active only when the thermostat for the
pan with the water level sensor is turned ON .
4. Make sure the drain valve is fully closed before turning any
thermostats ON.
5. The autofill function is only activated when the far left
thermostat is turned ON. For manifolded autofill warmers, be
sure to turn far left thermostats ON before turning any other
control ON, to avoid heating a dry pan.
6. DO NOT use autofill warmers in the dry mode. This may
damage the water level sensor probe. NEVER turn the
thermostat ON for the pan with the probe and fill tube unless
the entire warmer unit is to be used in the wet mode.
7. Clean water level sensor daily to maintain water level in
warmer.
DO NOT use autofill
warmers in the dry mode.
This may damage the water
level sensor. NEVER turn the
thermostat ON for the pan
with the sensor and fill tube
unless the entire warmer unit
is to be used in the wet
mode.
OPERATION
7
011 303308 OpManual for Built-In T’Stat Warmers