Wells H-2412G Food Warmer User Manual


 
TROUBLESHOOTING
10
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Pilot will not light Gas supply off Check main / unit gas valves
Air in lines Turn gas valve on. Attempt to
light pilot every 15 sec.
Pilot valve not on Turn pilot valve on / adjust
Pilot burner holes are plugged Clean pilot burner
Front or rear burner
won’t light
Actuator not depressed Burner should light only when a
pot or pan depresses actuator.
Be sure actuator is properly
assembled to arm
Pilot flame not lit Turn off gas — allow unit to
vent for 5 minutes. Turn gas
back on and light both pilots
Control not on Turn temperature control to HI
Set to desired setting when lit
Water in burner Remove burner and dry
thoroughly
Damaged temperature control
valve, burner, actuator valve or
other internal component
Contact Authorized Wells
Service Agency for repairs
Burner not hot enough Control valve not set Adjust for desired temperature
Shutter or nozzle out of
adjustment
Contact qualified technician for
adjustment
Damaged temperature control
valve, burner actuator or other
internal component
Contact Authorized Wells
Service Agency for repairs
NOTE: There are no user serviceable components in the burner assemblies or in the control valves.
In all cases of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
M228 306916 OpM H-2412 Instant-On Dual Pilot Gas Hotplate