Whirlpool 2314473B Refrigerator User Manual


 
15
PRODUCT DATA SHEETS
Base Grille Water Filtration System
Model WF-L200V Capacity 200 Gallons (757 Liters)
Model WF-NL120V Capacity 120 Gallons (454 Liters)
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-L200V: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filters rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filters rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement filter L200V / NL120V, part
#4396701. 2007 suggested retail price of $34.99 U.S.A./
$45.99 Canada. Prices are subject to change without notice.
Model WF-NL120V: Change the water filter every
6 months. Use replacement filter L200V / NL120V, part
#4396701. 2007 suggested retail price of $34.99 U.S.A./
$45.99 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the front cover or Accessories section for the
Manufacturers name, address and telephone number.
Refer to the Warranty section for the Manufacturers limited
warranty.
Application Guidelines/Water Supply Parameters
System tested and certified by NSF International against NSF/ANSIStandard 53 for
the reduction of Lead, Mercury, Benzene, p-dichlorobenzene, O-Dichlorobenzene,
Toxaphene, Ethyl Benzene, 1,2,4-trichlorobenzene and against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor and Particulate Class III.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average%
Reduction
Chlorine Taste/Odor
Particulate Class lll
*
50%
85%
1.9 mg/L
49333/mL
2.0 mg/L ± 10%
At least 10,000 particles/mL
0.07 mg/L
640/mL**
0.06 mg/L
312/mL
>75%
98.7%
>75%
99.0%
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average%
Reduction
Lead:@ pH 6.5
Lead: @ pH 8.5
0.01mg/L
0.01mg /L
0.14 mg/L
0.15 mg/L
0.15 mg/L ± 10%
0.15 mg /L ± 10%
0.0014 mg/L
0.0069 mg/L
0.0011 mg/L
0.0042 mg/L
99.00%
95.40%%
99.21%
97.20%
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.0059 mg/L
0.0054 mg/L
0.006 mg/L ± 10%
0.006 mg /L ± 10%
0.0009 mg/L
0.0007mg /L
0.0004 mg/L
0.00043 mg/L
84.74%
87.03%
93.22%
92.03%
Benzene 0.005 mg/L 0.0157 mg/L 0.015 mg/L ± 10% 0.002 mg/L 0.00083 mg/L 87.26% 94.71%
p-dichlorobenzene 0.075 mg/L 0.210 mg/L 0.225 mg/L ± 10% 0.0005 mg/L 0.0005 mg/L 99.76% 99.76%
O-Dichlorobenzene 0.60 1.84 1.8 ± 10% 0.20 0.0418 89.13 97.73
Toxaphene 0.003 0.0143 0.015 ± 10% 0.0012 0.0010 91.60 93.00
Ethyl Benzene 0.70 2.00 2.1 ± 10% 0.40 0.085 80.00 95.75
1,2,4- trichlorobenzene 0.07 0.232 0.21 ± 10% 0.0041 0.0016 98.23 99.31
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 GPM (1.9 L/min.) @ 60 psi.
*
**
Class Ill particle size: > 5 to < 15 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.