Whirlpool FGP300JN0 Range User Manual


 
Operating position
C
5.Remove cardboard shipping base from
under range. Open broiler door. Use a 3/8”
drive ratchet to lower rear leveling legs one-
half turn. Use channel lock pliers to lower front
leveling legs one-half turn.
7. If installing the range in a mobile
home, you MUST secure the range to the floor.
Any method of securing the range is adequate as
long as it conforms to the “Manufactured Home
Construction and Safety Standard,” Page 2.
8.Place rack in oven. Place level on rack,
first side to side; then front to back.
If range is not level, pull range forward until
rear leveling leg is removed from the anti-tip
bracket. Use 3/8" drive ratchet and channel
lock pliers to adjust leveling legs up or down
until range is level. Push range back into
position. Check that rear leveling leg is
engaged in anti-tip bracket.
Note: Oven must be level for satisfactory
baking conditions.
Page 5
Before moving range across floor, check that
range is still on cardboard shipping base to
protect floor covering.
Gas connection
D
10. If a flexible appliance connector is
used, be certain connector is not kinked.
11. Check that all control knobs are in the
“OFF” position.
12.Open the manual shutoff valve in the
gas supply line. Wait a few minutes for gas to
move through the gas line.
13.Use a brush and liquid detergent
to test all gas connections. Bubbles around
connections will indicate a leak. If a leak appears,
shut off gas valve controls and tighten
connections. Then check connections again.
Never test for gas leaks with a match or other
flame. Clean all detergent from gas connections.
Close broiler door.
15.If pilot needs adjusting, remove
burner grates, burners and screws. Lift
cooktop.
Note: There is no cooktop support rod.
14.Light the burner pilots.
1. Remove burner grates.
2. Place a lit match through the small pilot
holes in the cooktop located between front
and rear burners.
3. After lighting, you must see a pilot flame
in each pilot hole.
Note: The pilot flames should be 1/2” to
5/8” inch high.
rear leveling leg
front leveling leg
manual shutoff valve
“open” position
gas supply
to range
9.Assemble the flexible connector to the
gas supply pipe to the pressure regulator
connection fitting, using the adapter fittings
provided with the flexible connector. Use pipe-
joint compound made for use with L.P. gas to
seal all pipe thread connections.
16.Adjust pilot adjustment screw until
pilot flame tips are 1/2" to 5/8” high and
centered in the pilot housings. If the flame is
too high, carbon (soot) will form on
underside of maintop.
17.Open broiler door. Hold a match to
the opening in the top of the pilot area at the
rear of the oven burner. No pilot adjustments
are needed. Close broiler door.
pilot
lights
front of range
pilot
adjustment
screw
screw
burner
regulator
connection
fitting
6.Making sure the
anti-tip bracket is
installed:
• Look for the
anti-tip bracket
securely attached to
floor.
• Slide range back so rear range foot is under
anti-tip bracket.
anti-tip
bracket
range foot
All connections must be wrench-tightened.
1/2" to 3/4"
gas pipe
nipple
adapter
adapter
manual
gas
shutoff
valve
manual
gas
shutoff
valve
black iron
pipe
A 1/2" male pipe thread is needed for connection to
pressure regulator female pipe threads.
union
pressure regulator
connection fitting
90˚elbow
1/2" to 3/4"
gas pipe
pressure regulator
connection fitting
Typical rigid pipe connection
Typical flexible connection
flexible
connector
use pipe-joint
compound
use pipe-joint
compound
pilot holes