-".o/,'~" ,
7 .Electrical Data
Base level
Voltage 220/230/50 VIV/Hz
Total power app. 3 kW
Fuses 10/16 A
Water connection up to 25 °C
Timer
Model EC 4326
Basic step times 15",45",60" 120", 270"
Heating
1 Element system: 220 V 2800/1800 W app. 16,0 Ohm
230 V 3060 W app. 17,0 Ohm
2 Element system: (CH + DK)
Element A 220 V 1850 W app. 25,3 Ohm
Element B 220 V 950 W app. 49,5 Ohm
Motor
SP -Motor 220 V/130 W HI=121 Ohm HA=30 Ohm
Capacitor 3 IJF
DP Motor 220/240 V 30 W 170 Ohm
Timer motor 220/240 V 5640 + 400 Ohm
Valve
Inlet valve
Double valve 220/240 V 6 W 3620 Ohm
Regeneration valve 220/240 V 8 W 2300 Ohm
Relay
Relay 220/240 V 50/60 Hz 5500 Ohm
Thermostats Indication colour
Thermostat without 40 °C SP 40 :t 3 °C RSP 29 :t 5 °C
Thermostat red 55 °C SP 55 :t 3 °C RSP 40 :t 5 °C
Thermostat white 65 °C SP 68 :t 3 °C RSP 57 :t 5 °C
Housing colour brown
Reset
Safety thermostat with manual reset SP 180 :t 7 °C
8. Water Levels
Basic level SP 137 :t 5 RSP 40 :t 5 mm ws
Working level SP 137 :t 5 RSP 40 :t 5 mm ws
Safety level SP 150 :t 5 RSP 100 :t 5 mm ws
9. Water Measuring
Basic level 125 mm
Working level 125 mm
Safety level 136 mm
10. Regenerating Steps and Volumes
Figure Volume Steps Water hardness
Figure 360 cm3 24 < 30° dh = < 5,0 mmol/ I