Whirlpool 761883306 Ventilation Hood User Manual


 
16
W Lift range hood into final
position, feeding electrical wire through
wiring opening. Position the range hood so
that the large end of the keyhole slots are
over the screws, Then push the hood
toward the wall so that the screws are in the
neck of the slots. Tighten mounting screws
to cabinet, making sure mounting screws
are in narrow neck of slots. Make sure that
damper blade, if used, rotates up and
down freely.
screw
17
W Connect the white and black
wires of the power supply cable to the
white and black leads in the hood with
twist-on connectors.
Connect the power supply grounding wire
to the green, grounding wire inside the
range terminal box with a twist-on wire
connector.
Use caulking to seal wire opening.
Replace terminal box cover.
18
n
Pull firmlv on tab to remove
filter/light lens from range hood. Turn
filter/light lens so that charcoal filter pad is
facing up. Lift tabs and remove charcoal
filter pad. Discard charcoal filter pad. Place
edge of filter/light lens in opening so that
right side is above flange and tab faces
downward. Press filter/light lens into position.
Non-vented
installation
W Put on safety glasses and gloves.
2
1 Check vent baffle on top of range
hood. “Non-vented” should be facing up.
3
n
Remove knockout from the wiring
opening (rear or top) to be used.
Do Not remove venting knockouts.
5.1516.
-
4
H Remove terminal box cover on
range hood.
Injury Hazard
More than one person is required to help
with installation because of the weight
and size of range hood.
Failure to follow this instruction could
result in serious injury.
keyhole slot
5
n
Lift range hood into final position
and center. Mark on underside of cabinet
the location for the four keyhole mounting
slots. Set range hood aside on a protected
surface.
6
H Determine and clearly mark a
vertical centerline in the cabinet opening.
centerline
7
n
TO wire through top, mark a line
7-l /2” from the right of the centerline on the
underside of the cabinet. Mark the point on
this line that is l-3/8” from the back wall. Drill
a l-l /4” diameter hole through cabinet at
this point.
centerline
To wire through rear, mark a line 7-l /2” from
the right of the centerline on the wall. Mark
the point on this line that is 64-5J8” from the
floor (or l-3/8” from underside of cabinet).
Drill a l-l /4” diameter hole through wall at
this point.
8
n
Complete Steps 14-l 7. Do Not
complete Step 18. The charcoal filter pad is
needed in non-vented installation.
/Li!fs!fiiJ!L~
Keep Installation lnstruchons
( Congratulations! )
reference. The instructions will
make reinstalling your Whirlpool
range hood in another home
as easy as the first
installation.
Panel D