14
PRODUCT DATA SHEETS
Base Grille Water Filtration System
Model WF-L200V Capacity 200 Gallons (757 Liters)
Model WF-NL120V Capacity 120 Gallons (454 Liters)
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in ANSI/NSF 42/53.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
■ It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
■ Model WF-L200V: The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement filter L200V /NL120V, part
#4396701. 2005 suggested retail price of $32.99 U.S.A./
$45.99 Canada. Prices are subject to change without notice.
Model WF-NL120V: Change the water filter every
6-9 months. Use replacement filter L200V / NL120V, part
#4396701. 2005 suggested retail price of $32.99 U.S.A./
$45.99 Canada. Prices are subject to change without notice.
■ The product is for cold water use only.
■ Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
■ Refer to the front cover or “Accessories” section for the
Manufacturer’s name, address and telephone number.
■ Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average%
Reduction
Chlorine Taste/Odor
Particulate Class lll
*
≥50%
≥85%
1.9 mg/L
49333/mL
2.0 mg/L ± 10%
At least 10,000 particles/mL
0.07 mg/L
640/mL**
0.06 mg/L
312/mL
>75%
98.7%
>75%
99.0%
Contaminant
Reduction
NSF Reduction
Requirements
Average
Influent
Influent Challenge
Concentration
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average%
Reduction
Lead:@ pH 6.5
Lead: @ pH 8.5
0.01mg/L
0.01mg /L
0.14 mg/L
†
0.15 mg/L
†
0.15 mg/L ± 10%
0.15 mg /L ± 10%
0.0014 mg/L
0.0069 mg/L
0.0011 mg/L
0.0042 mg/L
99.00%
95.40%%
99.21%
97.20%
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.0059 mg/L
0.0054 mg/L
0.006 mg/L ± 10%
0.006 mg /L ± 10%
0.0009 mg/L
0.0007mg /L
0.0004 mg/L
0.00043 mg/L
84.74%
87.03%
93.22%
92.03%
Benzene 0.005 mg/L 0.0157 mg/L 0.015 mg/L ± 10% 0.002 mg/L 0.00083 mg/L 87.26% 94.71%
p-dichlorobenzene 0.075 mg/L 0.210 mg/L 0.225 mg/L ± 10% 0.0005 mg/L 0.0005 mg/L 99.76% 99.76%
O-Dichlorobenzene 0.60 1.84 1.8 ± 10% 0.20 0.0418 89.13 97.73
Toxaphene 0.003 0.0143 0.015 ± 10% 0.0012 0.0010 91.60 93.00
Ethyl Benzene 0.70 2.00 2.1 ± 10% 0.40 0.085 80.00 95.75
1,2,4- trichlorobenzene 0.07 0.232 0.21 ± 10% 0.0041 0.0016 98.23 99.31
System tested and certified by NSF International against NSF/ANSI
Standard 53 for the reduction of Lead, Mercury, Benzene,
p-dichlorobenzene, O-Dichlorobenzene, Toxaphene, Ethyl Benzene,
1,2,4-trichlorobenzene and against NSF/ANSI Standard 42 for the
reduction of Chlorine Taste and Odor and Particulate Class III.
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33
° - 100°F (0.6° - 37.8°C)
0.5 GPM (1.9 L/min.) @ 60 psi.
*
**
†
Class Ill particle size: > 5 to < 15 um
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.