Whirlpool EV150C Freezer User Manual


 
Install properly.. Remove sales labels...
Remove the Consumer Buy Guide label and any
lnslde labels before using the freezer
To remove any remalnlng glue:
1. Rub briskly with thumb to make a ball, then
remove.
OR
2. Soak area with dishwashing detergent solution [I
teaspoon detergent in 1 quart warm water] be-
fore removing glue as described in step 1.
DO NOT USE rubbing alcohol or flammable or
toxic solvents, such as acetone, gasoline, car-
bon tetrachlorlde, etc. These can damage the
material.
NOTE: DO NOT REMOVE the Tech Sheet fas-
tened under the treezer at the front.
Clean it . . .
1 Check the strength of the floor. It should hold the
werght of a fully loaded freezer.
2. Pick a safe place, indoors, away from in-
flammables such as gasoline.
3 Allow 3 Inches (7.5 cm] air space on top of freezer
for proper ventrlation
Clean your freezer before
using it. See cleaning
instructions on page 6
4 Allow at least an inch (2 5 cm] between the
freezer condenser, on the back of the unrt. and
the wall
5 Allow % Inch (1 25 cm] on each srde of the freezer
for ease of Installation.
6 If the freezer IS to be against a wall, you might
want to leave extra space on the hinge side so the
door can be opened wrder
Level freezer...
so the door will stay
Plug it in...
Sprang grounding
type wall receptacle
open at any position
Raise
Lower
I, Keep the 4 bolts that hold refrigerator in shrpping
crate. They are the levelling legs.
2. Screw these bolts all the way into bolt holes at the
bottom corners of refrigerator. Move refrigerator
into place.
Freezer
Power Cord
grounding
I
PM
Recommended Grounding Method
3. Adjust each leg until the refrigerator won’t rock.
4. Adjust front legs to level the refrigerator
-
To raise corners, turn legs in direction shown.
~ To lower corners, turn legs in direction shown.
5. Check with level.
A 115 Volt, 60 Hz, AC only 15 or 20 ampere fused
and properly grounded electrical supply is re-
quired. It IS recommended that a separate circuit
serving only thus appliance be provided.
Do not use an extension cord. Use a recep-
tacle which cannot be turned off with a switch
or pull chain. See individual electrical require-
ments and grounding instruction sheet in your liter-
ature package.
4