Whirlpool G7CG3064X Cooktop User Manual


 
CABINET DIMENSIONS
B
D
A
C
E
F
H
I
J
G
K
L
M
J
NOTES: After making the countertop cutout, some installations may require
notching down the base cabinet side walls to clear the cooktop base. To avoid this
modification, use a base cabinet with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the countertop to the
top of the drawer (or other obstruction) in base cabinet is required. The drawer
depth may need to be shortened to avoid interfering with the regulator.
IMPORTANT: If an undercounter built-in wall oven is to be installed below this
cooktop, the grounded outlet (H) and gas supply piping must be located in an
adjacent cabinet.
This cooktop and its gas and electrical supply sources must be installed before the
undercounter built-in wall oven is installed.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10526073A
2/13/13
Page 2 of 2
A.30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models
B.Combustible area above countertop (shown by dashed
box above)
C.30" (76.2 cm) minimum clearance between top of cooktop
platform and bottom of uncovered wood or metal cabinet
(24" [61 cm] minimum clearance if bottom of wood or metal
cabinet is covered by not less than ¼ " [0.6 cm] flame retardant
millboard covered with not less than No. 28
MSG sheet steel, 0.015" [0.04 cm] stainless steel, or
0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D.13" (33 cm) recommended upper cabinet depth
E.3 " (7.9 cm)
F. 19" (48.3 cm)
G.18" (45.7 cm) minimum clearance from upper cabinet to
countertop within minimum horizontal clearances to cooktop
H.Grounded outlet - Locate within 24" (61 cm) of right rear
corner of cutout (with no undercounter built-in oven installed
below cooktop)
J.8 " (21.3 cm) minimum distance to nearest left and right side
combustible surface
K.2 " (7.3 cm) minimum distance to rear combustible surface
L.Gas line opening - Wall: Anywhere 5" (12.7 cm) below
underside of countertop. Cabinet floor: anywhere within
6" (15.2 cm) of rear wall is recommended (with no
undercounter built-in oven installed below cooktop)
M.25" (63.5 cm) minimum countertop depth is required
¼
8
¼
8
3
¼
8
7
IMPORTANT: If installing a range hood or microwave hood combination above
the cooktop, follow the range hood or microwave hood combination installation
instructions for dimensional clearances above the cooktop surface.
PRODUCT DIMENSIONS (cont.)
30" (76.2 cm) Model (W5CG3024)
36" (91.4 cm) Model (W5CG3625)
A.21½" (54.6 cm)
B.29½" (75.0 cm)
C.18
²⁹⁄₃₂
" (48.0 cm)
D.28½" (72.4 cm)
E.3
²¹⁄₃₂
" (9.3 cm)
F. 4
¹⁹⁄₃₂
" (11.6 cm)
G.10
⁷⁄₈
" (27.6 cm)
E
B
G
F
A
C
D
A.21" (53.3 cm)
B.36" (91.4 cm)
C.18
²⁹⁄₃₂
" (48.0 cm)
D.34½" (87.6 cm)
E.3
³⁄₈
" (8.6 cm)
F. 4
¹¹⁄₃₂
" (11.0 cm)
G.7½" (19.1 cm)
B
G
F
D
A
E
C